产品型号:Thermosel
更新时间:2025-06-19
厂商性质:代理商
访 问 量 :112
020-66618088
技术参数:
Thermosel加热器粘度测量范围cP(mPa·S)
SPINDLESAMPLE VOLUMESHEAR RATE(sec-')+MODEL | SC4-18 8mL 1.32N | SC4-31 10mL .34N | SC4-34 9.5mL .28N | SC4-21 8ml .93N | SC4-27* 10.5mL .34N | SC4-28 11.5mL .28N | SC4-29 13mL .25N | HT-DIN-81** 7mL 1.29N |
DVNXLV | 1.2-30K | 12-300K | 24-600K | Not applicable for historical reasons. However, it is possibleto use the above spindles with any of these instruments3.4-10Kto use the above spindles with any of these instrumentsif you require information on viscosity range. | 1.0-10K | |||
DV2TLV | 1.5-30K | 15-300K | 30-600K | 3.4-10K | ||||
DVPLLV | 1.5-30K | 15-300K | 30-600K | 3.4-10K | ||||
LVT | 5-10K | 50-100K | 100-200K | 5.7-10K | ||||
DVNXRV | However, it is possible to use the abovespindles with any of these instruments.Digital Viscometers/Rheometers willautomatically calculate viscosity. Pleaseyou require information on viscosity range. | 20-500K | 100-2.5M | 200-5M | 400-10M | 14.6-10K | ||
DV2TRV | 25-500K | 125-2.5M | 250-5M | 500-10M | 36.5-10K | |||
DVPLRV | 25-500K | 125-2.5M | 250-5M | 500-10M | 36.5-10K | |||
RVT | 50-100K | 250-500K | 500-1M | 1K-2M | 36.5-10K | |||
DVNXHA | 40-1M | 200-5M | 400-10M | 800-20M | 29.2-10K | |||
DV2THA | 50-1M | 250-5M | 500-10M | 1K-20M | 73.0-10K | |||
DVPLHA | 50-1M | 250-5M | 500-10M | 1K-20M | 73.0-10K | |||
HAT | 100-200K | 500-1M | 1K-2M | 2K-4M | 73.0-10K | |||
DVNXHB | 160-4M | 800-20M | 1.6K-40M | 3.2K-80M | 116.8-10K | |||
DV2THB | 200-4M | 1K-20M | 2K-40M | 4K-80M | 292.0-10K | |||
DVPLHB | 200-4M | 1K-20M | 2K-40M | 4K-80M | 292.0-10K | |||
HBT | 400-800K | 2K-4M | 8K-16M | 4K-8M | 292.0-10K |
M=1 milionK=1t
housandN= RPMtSpindle SC4-18 1.32x 10 (rpm)= 13.2 sec-1 cP= Centipoise mPa*s = miliPascalseconds
*可选择100个包装的一次性转子SC4-27D,订货编号:SC4-27D-100,需要特殊的接头适配器,订货号:SC4-DSY。
**81号转子,订货编号:HT-DIN-81,适用于HT-2或HT-2DB样品杯。
性能特点:
有助于稳定测试环境的几个因素:
温控波动小。
样品量小,且样品杯的隔热性能好,可有效减少样品温度不均的现象。
旋转的转子起到了搅拌的作用。
测试过程步骤简单明了。用户熟悉仪器以后,无需太多技巧就可以轻松获得准确且重现性好的数据。
特性和优点
样品加温控制最高温度可达+300°C
可编程控制器可提供单点设定点或高达10个温度点的设定。可用RheocalcT软件来设置点之间的温度梯度
注意:采用RheocalcT软件进行质量控制时,要求选配HT-106电缆。
可与Brookfield标准粘度计和DVNext流变仪一起使用
注意:与DVNext流变仪配套使用时,要求选配DVP-141电缆。
配备可重复使用的不锈钢盛样器和五个一次性铝制样品杯
输出: 0-4 VDC适用于图表记录器;RS-232适用于与DVNext和/或RheocalcT 软件配套使用。